  • TZT10WSOT-23Zener diode, 3 pins, Taitron ComponentsZener diodeSOT-233 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Details
    SMD Zener Diodes (Three Terminals) - 200mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • EMF20N02JSSOT-23N-channel MOSFET, 3 pins, Excelliance MOSN-channel MOSFETSOT-233 pinsExcelliance MOS
    What it is
    N-channel MOSFET
    Maker
    Excelliance MOS
    Package
    SOT-23
    Pins
    3
    Details
    20 V, 6 A N-channel MOSFET
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • EIA-96:100603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
    What it is
    Precision resistor (EIA-96 code)
    Maker
    Not recorded
    Package
    0603
    Pins
    2
    Details
    EIA-96 precision chip resistor, code 10 stands for 124 in the E96 table; the printed mark adds a multiplier letter (10A = 124 Ohm, 10B = 1.24 kOhm)
    Source
    Added by hand from a published table

    Is it dead? The meter test is below: Resistor.

  • 1PS59SB10SOT-233 pins, NexperiaNot recordedSOT-233 pinsNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    30V 0.2A schottky diode
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • AP8822C-50GASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AP8822C-50GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AP8822C-50PASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 8 more parts have no package on record
    • USFZ10VZener diode, KECZener diodeNot recordedNot recordedKEC
      What it is
      Zener diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • VCUT10G1-SD0ESD protection diode, VishayESD protection diodeNot recordedNot recordedVishay
      What it is
      ESD protection diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Bidirectional Symmetrical (BiSy) Single Line ESD-Protection Diode in Silicon Package
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • 02DZ10XZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 9.40..9.93V, Iz=5mA, Zz=15, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • 02DZ10YZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 9.73..10.26V, Iz=5mA, Zz=15, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • 02DZ10ZZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 10.06..10.60V, Iz=5mA, Zz=15, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • AP8822C-50GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.0V±2%, -Reset PPO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8822C-50GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.0V±2%, -Reset PPO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8822C-50PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.0V±2%, -Reset PPO, 200ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Resistor

Ohms range, across it, power off.

Working, it reads

Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

Dead, it reads

  • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
  • Well above its marked value: drifted high.
  • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
On the board:
A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
Compare:
The same position on another channel usually carries the same value, and so does the matching part on another board.
Watch for:
A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.