SMD code 15A
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
15A on a chip resistor
140 Ω
140 Ω resistor, 1%
EIA-96 precision code: 15 stands for 140 in the E96 table, and the letter A is the multiplier, × 1. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 140 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 140 Ω on the board is a fault. Open, or well above 140 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 140 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SMB, SMA, SOT-23), 15A is a part code instead. Those parts are listed below.
79 parts are printed 15A
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
P4SMA15ASMATVS diode, 2 pins, DOWOTVS diodeSMA2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMAJ15ASMATVS diode, 2 pins, Taitron ComponentsTVS diodeSMA2 pinsTaitron Components
- What it is
- TVS diode
- Maker
- Taitron Components
- Package
- SMA
- Pins
- 2
- Details
- SMD TVS - 400W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMB15ASMBTVS diode, 2 pins, DOWOTVS diodeSMB2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMB15A(MS)SMBTVS diode, 2 pins, MSKSEMITVS diodeSMB2 pinsMSKSEMI
- What it is
- TVS diode
- Maker
- MSKSEMI
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMBF15ASMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMBF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMBJ15ASMBTVS diode, 2 pins, Taitron ComponentsTVS diodeSMB2 pinsTaitron Components
- What it is
- TVS diode
- Maker
- Taitron Components
- Package
- SMB
- Pins
- 2
- Details
- SMD TVS - 600W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P15SMCJ15ASMCFTVS diode, 2 pins, Formosa MicrosemiTVS diodeSMCF2 pinsFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- SMCF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM30DOAA15ASMBTVS diode, 2 pins, ProTek DevicesTVS diodeSMB2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMB
- Pins
- 2
- Details
- 600 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM35DOAB15ASMCTVS diode, 2 pins, ProTek DevicesTVS diodeSMC2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMC
- Pins
- 2
- Details
- 1500 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PTVS15ADFNESD protection diode, ProTek DevicesESD protection diodeDFNNot recordedProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- DFN
- Pins
- Not recorded
- Details
- 3000W TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
S-13D1B3018-M6T1U3SOT-23-6LDO regulator, 6 pins, ABLICLDO regulatorSOT-23-66 pinsABLIC
- What it is
- LDO regulator
- Maker
- ABLIC
- Package
- SOT-23-6
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
S-LMBZ15VALT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 14.25 V, VZ Nom 15 V, VZ Max 15.75 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
3 more parts have no package on record
P4SMASF15ATVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PLZ15AZener diode, VishayZener diodeNot recordedNot recordedVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 15 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-13D1B3018-A6T2U3LDO regulator, ABLICLDO regulatorNot recordedNot recordedABLIC
- What it is
- LDO regulator
- Maker
- ABLIC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.