15A on a chip resistor

140 Ω

140 Ω resistor, 1%

EIA-96 precision code: 15 stands for 140 in the E96 table, and the letter A is the multiplier, × 1. These are 1% parts.

Check it with a meter

Lift one end and measure across it. A good one reads 140 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 140 Ω on the board is a fault. Open, or well above 140 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 140 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SMB, SMA, SOT-23), 15A is a part code instead. Those parts are listed below.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • PSMCJ15ASMCTVS diode, 2 pins, Lite-On SemiconductorTVS diodeSMC2 pinsLite-On Semiconductor
    What it is
    TVS diode
    Maker
    Lite-On Semiconductor
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=12.8V, Vbr=14.3..15.8V, Ipp=70.8A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PZM15NB2ASOT-233 pins, NXPNot recordedSOT-233 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-23
    Pins
    3
    Details
    dual ca 15V 0.3W zener
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • SMA6F15ASMATVS diode, 2 pins, Bruckewell TechnologyTVS diodeSMA2 pinsBruckewell Technology
    What it is
    TVS diode
    Maker
    Bruckewell Technology
    Package
    SMA
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMAJ15ASMATVS diode, 2 pins, SynSemiTVS diodeSMA2 pinsSynSemi
    What it is
    TVS diode
    Maker
    SynSemi
    Package
    SMA
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMAJP4KE15ASMATVS diode, 2 pins, Micro Commercial ComponentsTVS diodeSMA2 pinsMicro Commercial Components
    What it is
    TVS diode
    Maker
    Micro Commercial Components
    Package
    SMA
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=12.80V, Vbr=14.30..15.80V, Ipp=19.3A, 400W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBG15ASMBGTVS diode, 2 pins, Microsemi Integrated Products DivisionTVS diodeSMBG2 pinsMicrosemi Integrated Products Division
    What it is
    TVS diode
    Maker
    Microsemi Integrated Products Division
    Package
    SMBG
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJP6KE15ASMBTVS diode, 2 pins, Micro Commercial ComponentsTVS diodeSMB2 pinsMicro Commercial Components
    What it is
    TVS diode
    Maker
    Micro Commercial Components
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=12.80V, Vbr=14.30..15.80V, Ipp=28.8A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMCJ1.5KE15ASMCTVS diode, 2 pins, Micro Commercial ComponentsTVS diodeSMC2 pinsMicro Commercial Components
    What it is
    TVS diode
    Maker
    Micro Commercial Components
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=12.80V, Vbr=14.30..15.80V, Ipp=71.7A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMCJ15ASMCTVS diode, 2 pins, SynSemiTVS diodeSMC2 pinsSynSemi
    What it is
    TVS diode
    Maker
    SynSemi
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TV15CJ150A-GSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vbr=14.25..15.75V, Vrwm=12.8V, Ipp=70.75A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TVP04A150A-GSMATVS diode, 2 pins, ComchipTVS diodeSMA2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMA
    Pins
    2
    Details
    Transient voltage supressor: Vbr=14.25..15.75V, Vrwm=12.8V, Ipp=18.87A, 400W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TVP06B15A-GSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=12.8V, Vbr=14.25..15.75V, Ipp=28.30A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3 more parts have no package on record
    • RKZ15AKUZener diode, RenesasZener diodeNot recordedNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 13.44..14.13V, Izt=10mA, Zzt=40, 500mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • SZP6SMB15ATVS diode, onsemiTVS diodeNot recordedNot recordedonsemi
      What it is
      TVS diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=15V, Vbr=14.3..15.8V, 28.3A, 600W(1ms)
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • TK74015LTokNot recordedNot recordedNot recordedTok
      What it is
      Not recorded
      Maker
      Tok
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: Dual, LDO, Separate CE, 1,5+1,5V±2%, 300mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?