SMD code 24-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
203 parts are printed 24-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
P4SOD24ASOD-123TVS diode, 2 pins, WeEn SemiconductorsTVS diodeSOD-1232 pinsWeEn Semiconductors
- What it is
- TVS diode
- Maker
- WeEn Semiconductors
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P6SMBF24SMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMBF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PDTC114ENSOT-883Digital transistor (NPN, resistors built in), 3 pins, PrisemiDigital transistor (NPN, resistors built in)SOT-8833 pinsPrisemi
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- Prisemi
- Package
- SOT-883
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), 0.1 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
PSBD2FD40V02SOD-882Schottky diode, 2 pins, PrisemiSchottky diodeSOD-8822 pinsPrisemi
- What it is
- Schottky diode
- Maker
- Prisemi
- Package
- SOD-882
- Pins
- 2
- Details
- Schottky diode, 40 V, 0.2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
PSOT24SOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23
- Pins
- 3
- Details
- 500W TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PSOT24-LF-T7SOT-233 pins, UMWNot recordedSOT-233 pinsUMW
- What it is
- Not recorded
- Maker
- UMW
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
RB511SM-30SOD-523Schottky diode, 2 pins, ROHMSchottky diodeSOD-5232 pinsROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RN1302,LFSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)SOT-5233 pinsHXY
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- HXY
- Package
- SOT-523
- Pins
- 3
- Details
- Digital transistor (bias resistors built in)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
S-L2SC3356WT1GSOT-323NPN transistor, 3 pins, LRCNPN transistorSOT-3233 pinsLRC
- What it is
- NPN transistor
- Maker
- LRC
- Package
- SOT-323
- Pins
- 3
- Details
- Bipolar transistor, NPN, IC 100 mA, VCEO 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
6 more parts have no package on record
NUF2450MUESD protection diode, onsemiESD protection diodeNot recordedNot recordedonsemi
- What it is
- ESD protection diode
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2 Line EMI Filter with ESD Protection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
NX5P2924UKLoad switch, NXPLoad switchNot recordedNot recordedNXP
- What it is
- Load switch
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Logic controlled high-side power switch
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
PSBD3DH40V2HSchottky diode, PrisemiSchottky diodeNot recordedNot recordedPrisemi
- What it is
- Schottky diode
- Maker
- Prisemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, 40 V, 2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR2VWM40ASchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR2VWM40ATFSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LMBR240ET1GSchottky diode, LRCSchottky diodeNot recordedNot recordedLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, VR 40 V, IF 2 A, VF Max 0.5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.