Skip to content

SMD code 24-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

203 parts are printed 24-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • TZD24WSSOD-323Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-3232 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-323
    Pins
    2
    Details
    SMD Zener Diodes (Two Terminals) - 200mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TZD24WTSOD-523Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-5232 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-523
    Pins
    2
    Details
    SMD Zener Diodes (Two Terminals) - 150mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TZD24WUSOD-723Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-7232 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-723
    Pins
    2
    Details
    SMD Zener Diodes (Two Terminals) - 100mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TZT24WSOT-23Zener diode, 3 pins, Taitron ComponentsZener diodeSOT-233 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Details
    SMD Zener Diodes (Three Terminals) - 200mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • WE24D5SOD-523ESD protection diode, 2 pins, WayonESD protection diodeSOD-5232 pinsWayon
    What it is
    ESD protection diode
    Maker
    Wayon
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • WE24D5-ATSOD-523ESD protection diode, 2 pins, WayonESD protection diodeSOD-5232 pinsWayon
    What it is
    ESD protection diode
    Maker
    Wayon
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • WS24DSOD-323ESD protection diode, 2 pins, WayonESD protection diodeSOD-3232 pinsWayon
    What it is
    ESD protection diode
    Maker
    Wayon
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ESD1006D24SOD-882ESD protection diode, 2 pins, YFWESD protection diodeSOD-8822 pinsYFW
    What it is
    ESD protection diode
    Maker
    YFW
    Package
    SOD-882
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ESD1610D24DFN1610-2ESD protection diode, 2 pins, YFWESD protection diodeDFN1610-22 pinsYFW
    What it is
    ESD protection diode
    Maker
    YFW
    Package
    DFN1610-2
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PESDNC5D24VULSOD-523ESD protection diode, 2 pins, PrisemiESD protection diodeSOD-5232 pinsPrisemi
    What it is
    ESD protection diode
    Maker
    Prisemi
    Package
    SOD-523
    Pins
    2
    Details
    ESD protection diode, 24 V working
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • EIA-96:240603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
    What it is
    Precision resistor (EIA-96 code)
    Maker
    Not recorded
    Package
    0603
    Pins
    2
    Details
    EIA-96 precision chip resistor, code 24 stands for 174 in the E96 table; the printed mark adds a multiplier letter (24A = 174 Ohm, 24B = 1.74 kOhm)
    Source
    Added by hand from a published table

    Is it dead? The meter test is below: Resistor.

  • 1SR156-400MELFRectifier, 2 pins, ROHMRectifierMELF2 pinsROHM
    What it is
    Rectifier
    Maker
    ROHM
    Package
    MELF
    Pins
    2
    Details
    Si-diode: 400V, 1A, Vf<1.3V(800mA)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • 3 more parts have no package on record
    • USFZ24VZener diode, KECZener diodeNot recordedNot recordedKEC
      What it is
      Zener diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • 02DZ2.4XZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 2.28..2.50V, Iz=5mA, Zz=100, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • 02DZ2.4ZZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 2.40..2.60V, Iz=5mA, Zz=100, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Resistor

Ohms range, across it, power off.

Working, it reads

Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

Dead, it reads

  • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
  • Well above its marked value: drifted high.
  • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
On the board:
A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
Compare:
The same position on another channel usually carries the same value, and so does the matching part on another board.
Watch for:
A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.