SMD code 5Hf
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, f, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 5H was searched.
117 parts are printed 5Hf
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BC808SOT-23Transistor, 3 pins, Taitron ComponentsTransistorSOT-233 pinsTaitron Components
- What it is
- Transistor
- Maker
- Taitron Components
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BZT52C16SOD-123FZener diode, 2 pins, DiotecZener diodeSOD-123F2 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CPDA3-5V0U-HFDFNESD protection diode, ComchipESD protection diodeDFNNot recordedComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- DFN
- Pins
- Not recorded
- Details
- 5 V unidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
G509L3ADTR1GSOT-563Load switch, 6 pins, Global Mixed-mode TechnologyLoad switchSOT-5636 pinsGlobal Mixed-mode Technology
- What it is
- Load switch
- Maker
- Global Mixed-mode Technology
- Package
- SOT-563
- Pins
- 6
- Details
- Power Distribution Switch
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
GSEV5U800SOD-523ESD protection diode, 2 pins, Good-ArkESD protection diodeSOD-5232 pinsGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- SOD-523
- Pins
- 2
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
JEU05D3USOD-323TVS diode, 2 pins, JieJieTVS diodeSOD-3232 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
JEU05D3U-AUSOD-323TVS diode, 2 pins, JieJieTVS diodeSOD-3232 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
KS05LL4SOT-553ESD protection diode, 5 pins, SeCoSESD protection diodeSOT-5535 pinsSeCoS
- What it is
- ESD protection diode
- Maker
- SeCoS
- Package
- SOT-553
- Pins
- 5
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
MM1Z 16SOD-123Zener diode, 2 pins, HottechZener diodeSOD-1232 pinsHottech
- What it is
- Zener diode
- Maker
- Hottech
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ 16 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM1Z 16LSOD-123FZener diode, 2 pins, HottechZener diodeSOD-123F2 pinsHottech
- What it is
- Zener diode
- Maker
- Hottech
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener diode, VZ 16 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM1Z16SOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
- What it is
- Zener diode
- Maker
- HXY
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, 27 V, 0.005 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM1Z16BWSOD-123Zener diode, 2 pins, JSMSEMIZener diodeSOD-1232 pinsJSMSEMI
- What it is
- Zener diode
- Maker
- JSMSEMI
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM1Z16WSOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
- What it is
- Zener diode
- Maker
- HXY
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, 22 V, 0.005 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
2 more parts have no package on record
ESDH5V0P1ESD protection diode, JSCJESD protection diodeNot recordedNot recordedJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LTVS16H5.0AT5GESD protection diode, LRCESD protection diodeNot recordedNot recordedLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V, IR @VRWM 0.3 μA, VBR Min 5.5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 5Hf
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 2 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.