SMD code 60C
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
60C on a chip resistor
41.2 kΩ
41.2 kΩ resistor, 1%
EIA-96 precision code: 60 selects 4.12 from the E96 series and C multiplies by 10000. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 41.2 kΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 41.2 kΩ on the board is a fault. Open, or well above 41.2 kΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 41.2 kΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23-6, USP-6C, SOT-23-5), 60C is a part code instead. Those parts are listed below.
11 parts are printed 60C
Not sure which one you have?
Answer up to 4 quick questions and these 11 parts are ranked, with a meter test that settles it. It works on a dead part too.
ET5H560CSOT-89-5LDO regulator, 5 pins, ETEKLDO regulatorSOT-89-55 pinsETEK
- What it is
- LDO regulator
- Maker
- ETEK
- Package
- SOT-89-5
- Pins
- 5
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
SM4F60CASOD-123FTVS diode, 2 pins, YFWTVS diodeSOD-123F2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMF60CASOD-123FTVS diode, 2 pins, JieJieTVS diodeSOD-123F2 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ELM990231ACSOT-89LDO regulator, 3 pins, ELM TechnologyLDO regulatorSOT-893 pinsELM Technology
- What it is
- LDO regulator
- Maker
- ELM Technology
- Package
- SOT-89
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 2.3V±2%, 300mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
IXD5127N55CMRSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 5.5V±0.8%, -Reset ODO, -MR, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
P4SMAFJ60CSMAFTVS diode, 2 pins, Dongguan You Feng Wei ElectronicsTVS diodeSMAF2 pinsDongguan You Feng Wei Electronics
- What it is
- TVS diode
- Maker
- Dongguan You Feng Wei Electronics
- Package
- SMAF
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=60V, Vbr=66.7..84.5V, Ipp=3.7A, 400W(1ms), Bidir.
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMAJ60CSMATVS diode, 2 pins, YeashinTVS diodeSMA2 pinsYeashin
- What it is
- TVS diode
- Maker
- Yeashin
- Package
- SMA
- Pins
- 2
- Details
- TVS: 60V, 3.7A, 400W (1ms), Bidirectional
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMFJ60CSOD-123FTVS diode, 2 pins, YeashinTVS diodeSOD-123F2 pinsYeashin
- What it is
- TVS diode
- Maker
- Yeashin
- Package
- SOD-123F
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=60V, Ipp=3.7A, 400W (1ms), Bidir.
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
RP102N151BSOT-23-5LDO regulator, 5 pins, RicohLDO regulatorSOT-23-55 pinsRicoh
- What it is
- LDO regulator
- Maker
- Ricoh
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, LN, 1.5V±1%, 300mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
SMBG60CSMBG2 pins, Microsemi Integrated Products DivisionNot recordedSMBG2 pinsMicrosemi Integrated Products Division
- What it is
- Not recorded
- Maker
- Microsemi Integrated Products Division
- Package
- SMBG
- Pins
- 2
- Details
- TVS: 60V, 5.6A, 600W(1ms), Bidirectional
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
XC6127N55CMRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 5.5V±0.8%, -Reset ODO, -MR, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 60C
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 28 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.