Skip to content

SMD code CS-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

89 parts are printed CS-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 2SA733SOT-23Transistor, 3 pins, SeCoSTransistorSOT-233 pinsSeCoS
    What it is
    Transistor
    Maker
    SeCoS
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • 2SA733-ESOT-23PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    -50V, -0.1A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA733-PSOT-23PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    -50V, -0.1A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA733-QSOT-23PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    -50V, -0.1A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • BZT52-C27SOD-123Zener diode, 2 pins, NexperiaZener diodeSOD-1232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX384B27SOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX384B27-Q1SOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CHT4124SGPSOT-363Dual NPN transistor, 6 pins, ChenmkoDual NPN transistorSOT-3636 pinsChenmko
    What it is
    Dual NPN transistor
    Maker
    Chenmko
    Package
    SOT-363
    Pins
    6
    Details
    General Purpose Transistor, 25 V, 200 mA
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor pair.

  • MBRX2150SOD-123FSchottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-123F2 pinsGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123F
    Pins
    2
    Details
    2A, 150V, Surface Mount Schottky Barrier Rectifiers
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • SMAJ43SMATVS diode, 2 pins, DOWOTVS diodeSMA2 pinsDOWO
    What it is
    TVS diode
    Maker
    DOWO
    Package
    SMA
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJ43CSMBTVS diode, 2 pins, DOWOTVS diodeSMB2 pinsDOWO
    What it is
    TVS diode
    Maker
    DOWO
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SN74LVC1G97DRYSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
    What it is
    Logic gate
    Maker
    Texas Instruments
    Package
    SON
    Pins
    6
    Details
    Configurable Multiple-Function Gate
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • SN74LVC1G97DSFSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
    What it is
    Logic gate
    Maker
    Texas Instruments
    Package
    SON
    Pins
    6
    Details
    Configurable Multiple-Function Gate
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • 2 more parts have no package on record
    • CPDWZ1V0SBPA-HFESD protection diode, ComchipESD protection diodeNot recordedNot recordedComchip
      What it is
      ESD protection diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      1 V bidirectional ESD protection diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • PMEG4020EPASSchottky diode, NexperiaSchottky diodeNot recordedNot recordedNexperia
      What it is
      Schottky diode
      Maker
      Nexperia
      Package
      Not recorded
      Pins
      Not recorded
      Details
      40 V, 2 A low VF Schottky barrier rectifier
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

NPN transistor pair

Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as CS-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 12 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.