Skip to content

SMD code ES in SOT-343

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • R3112Q461CSOT-3434 pins, RicohNot recorded4 pinsRicoh
    What it is
    Not recorded
    Maker
    Ricoh
    Package
    SOT-343
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 4,6V, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • DBTC-10-13X+RF coupler, Mini-CircuitsRF couplerNot recordedMini-Circuits
      What it is
      RF coupler
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      RF directional coupler, 5-1000 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • 2SC5817-SIsahaya ElectronicsNot recordedNot recordedIsahaya Electronics
      What it is
      Not recorded
      Maker
      Isahaya Electronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn: AF-Amp, 60V, 125mA, 100mW, 200MHz, B=270..560
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • 2SD27023 pins, ROHMNot recorded3 pinsROHM
      What it is
      Not recorded
      Maker
      ROHM
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • BD4856FVEVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 5,6V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD4856GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 5,6V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU46K304GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.0V±1%, -Reset PPO, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5109C43ANVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.3V±2%, +Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C41KNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.1V±0.8%, +Reset PPO, -MR, 800ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127N42ENRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.2V±0.8%, -Reset ODO, -MR, 800ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RP300K23AC2Voltage supervisor, RicohVoltage supervisorNot recordedRicoh
      What it is
      Voltage supervisor
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.32V±1%, +Reset PPO, -MR, Rdt=50ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RP602Z350CDC-DC converter, RicohDC-DC converterNot recordedRicoh
      What it is
      DC-DC converter
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM/VFM B-boost, 3.5V±1.5%, 1.5A, 2.6MHz, +CE, CL, Reset-pr.
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • SS10200HESchottky diode, PanjitSchottky diodeNot recordedPanjit
      What it is
      Schottky diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Details
      1A, 200V, Surface Mount Schottky Barrier Rectifiers
      Source
      Published code list

      Is it dead? The meter test is below: Schottky diode.

    • XC6109C43ANVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,3V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6119C43ANRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.3V±2%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as ES

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.