SMD code R
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
135 parts are printed R
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SB1197-RSOT-23PNP transistor, 3 pins, Weitron TechnologyPNP transistorSOT-233 pinsWeitron Technology
- What it is
- PNP transistor
- Maker
- Weitron Technology
- Package
- SOT-23
- Pins
- 3
- Details
- -32V, -0.8A, General Purpose PNP Bipolar Transistor
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
2SC2480SOT-233 pins, PanNot recordedSOT-233 pinsPan
- What it is
- Not recorded
- Maker
- Pan
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: VHF/UHF, 30V, 50mA, 150mW, B=800..1600, 1,3GHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC3932SOT-3233 pins, PanNot recordedSOT-3233 pinsPan
- What it is
- Not recorded
- Maker
- Pan
- Package
- SOT-323
- Pins
- 3
- Details
- Si-npn: HF-Amp, Osc, 30V, 50mA, 150mW, B=800..1600, >800MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
AX6903DASOT-323Voltage supervisor, 3 pins, AXElite TechnologyVoltage supervisorSOT-3233 pinsAXElite Technology
- What it is
- Voltage supervisor
- Maker
- AXElite Technology
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 3.08V±1.5%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BA585SOD-1232 pins, InfineonNot recordedSOD-1232 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-123
- Pins
- 2
- Details
- pin diode 50mA max
- Source
- Published code list
Is it dead? The meter test is below: PIN diode or varicap.
BA597SOD-1232 pins, InfineonNot recordedSOD-1232 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-123
- Pins
- 2
- Details
- PIN-diode: Attenuator, 50V, 100mA, >10MHz; code printed in yellow
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BB620SOD-1232 pins, InfineonNot recordedSOD-1232 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-123
- Pins
- 2
- Details
- C-diode: VHF-TV/VTR-Tuning, HBand, 30V, 20mA, 62..76pF; code printed in red
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BB644SOD-1232 pins, InfineonNot recordedSOD-1232 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-123
- Pins
- 2
- Source
- An older or alternative marking, from a published code list
Is it dead? The meter test is below: This part.
EL5108IW-T7SOT-23-66 pins, RenesasNot recordedSOT-23-66 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23-6
- Pins
- 6
- Source
- Published code list
Is it dead? The meter test is below: This part.
EL5127CYMSOP-1010 pins, RenesasNot recordedMSOP-1010 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- MSOP-10
- Pins
- 10
- Source
- Published code list
Is it dead? The meter test is below: This part.
ELM7537CCBSOT-343Voltage supervisor, 4 pins, ELM TechnologyVoltage supervisorSOT-3434 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-343
- Pins
- 4
- Details
- Voltage detector IC: 3.7V±2%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ELM7537CCCSOT-353Voltage supervisor, 5 pins, ELM TechnologyVoltage supervisorSOT-3535 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-353
- Pins
- 5
- Details
- Voltage detector IC: 3.7V±2%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ELM7537CEBSOT-323Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-3233 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 3.7V±2%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
2 more parts have no package on record
ATF-541M44 pins, BroadcomNot recordedNot recorded4 pinsBroadcom
- What it is
- Not recorded
- Maker
- Broadcom
- Package
- Not recorded
- Pins
- 4
- Details
- Low Noise Enhancement Mode Pseudomorphic HEMT
- Source
- Published code list
Is it dead? The meter test is below: This part.
BA895Diode, 2 pins, InfineonDiodeNot recorded2 pinsInfineon
- What it is
- Diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- 2
- Source
- An older or alternative marking, from a published code list
Is it dead? The meter test is below: Silicon diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.