Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

2 parts in SOT-23 are printed S1D

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SMBTA42SOT-23Transistor, 3 pins, InfineonTransistor3 pinsInfineon
    What it is
    Transistor
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: Bipolar transistor.

  • SMBTA42MSOT-235 pins, InfineonNot recorded5 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOT-23
    Pins
    5
    Details
    Si-npn: Vid, 300/300V, 200mA, 350mW, B>25, >50MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 1 more part has no package on record. Nothing rules it out, so it stays.
    • S10DHERectifier, Galaxy MicroelectronicsRectifierNot recordedGalaxy Microelectronics
      What it is
      Rectifier
      Maker
      Galaxy Microelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      1A, 200V, Surface Mount Standard Recovery Rectifiers
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as S1D

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.