SMD code T2 in SOD-123
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
9 parts in SOD-123 are printed T2
Not sure which one you have?
Answer up to 4 quick questions and these 39 parts are ranked, with a meter test that settles it. It works on a dead part too.
ABAV20W-HFSOD-123Switching diode, 2 pins, ComchipSwitching diode2 pinsComchip
- What it is
- Switching diode
- Maker
- Comchip
- Package
- SOD-123
- Pins
- 2
- Details
- 200 V, 200 mA switching diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20P-CSOD-123Switching diode, 2 pins, SeCoSSwitching diode2 pinsSeCoS
- What it is
- Switching diode
- Maker
- SeCoS
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20WSOD-123Switching diode, 2 pins, Galaxy MicroelectronicsSwitching diode2 pinsGalaxy Microelectronics
- What it is
- Switching diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20W-GSOD-123Switching diode, 2 pins, Taiwan SemiconductorSwitching diode2 pinsTaiwan Semiconductor
- What it is
- Switching diode
- Maker
- Taiwan Semiconductor
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20W-G3-08SOD-123Switching diode, 2 pins, HXYSwitching diode2 pinsHXY
- What it is
- Switching diode
- Maker
- HXY
- Package
- SOD-123
- Pins
- 2
- Details
- Switching diode, 250 V, 0.2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV20W-HFSOD-123Switching diode, 2 pins, ComchipSwitching diode2 pinsComchip
- What it is
- Switching diode
- Maker
- Comchip
- Package
- SOD-123
- Pins
- 2
- Details
- 200 V, 200 mA switching diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
MMSZ2V7SOD-123Zener diode, 2 pins, onsemiZener diode2 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-123
- Pins
- 2
- Details
- Zener Voltage Regulators MMSZxxxT1G Series, SZMMSZxxxT1G Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BAV19WSOD-123Switching diode, 2 pins, Diodes IncorporatedSwitching diode2 pinsDiodes Incorporated
- What it is
- Switching diode
- Maker
- Diodes Incorporated
- Package
- SOD-123
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
MMSZ2V7TSOD-123Zener diode, 2 pins, MotorolaZener diode2 pinsMotorola
- What it is
- Zener diode
- Maker
- Motorola
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode: 2.7V±5%, Izt=5mA, Zzt=100, 500mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
6 more parts have no package on record. Nothing rules them out, so they stay.
BAV20WS-GSwitching diode, Taiwan SemiconductorSwitching diodeNot recordedTaiwan Semiconductor
- What it is
- Switching diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
ESDA07CP30ESD protection diode, LeiditechESD protection diodeNot recordedLeiditech
- What it is
- ESD protection diode
- Maker
- Leiditech
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 7 V, Cj 15 pF
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDBLM12VB1ESD protection diode, JSCJESD protection diodeNot recordedJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LNP2010DT2AGP-channel MOSFET, LRCP-channel MOSFETNot recordedLRC
- What it is
- P-channel MOSFET
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- MOSFET, Complementary N&P-Channel, VDSS 20 V, VGS 12 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
NTB0102GFLogic level translator, 8 pins, NXPLogic level translator8 pinsNXP
- What it is
- Logic level translator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- 1 General description 2 Features and benefits 3 Ordering information
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NTB0102JKLogic level translator, 8 pins, NXPLogic level translator8 pinsNXP
- What it is
- Logic level translator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- 1 General description 2 Features and benefits 3 Ordering information
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as T2
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.