Skip to content

SMD code CD6 in SMA

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

1 part in SMA is printed CD6

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SMA6J26CSMATVS diode, Sunmate SemiconductorTVS diodeSunmate Semiconductor
    What it is
    TVS diode
    Maker
    Sunmate Semiconductor
    Package
    SMA
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=26V, Vbr=28.9..36.6V, Ipp=12.9A, 600W(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 5 more parts have no package on record. Nothing rules them out, so they stay.
    • CIMD6ACentral SemiconductorNot recordedCentral Semiconductor
      What it is
      Not recorded
      Maker
      Central Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN+PNP transistors: Dual, Sw, 50V, 100mA, 350mW, 250MHz, R1=4.7k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • IXD3235B36C0R-GDC-DC converter, IXYSDC-DC converterIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 3.6V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD3235B36C4R-GDC-DC converter, IXYSDC-DC converterIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 3.6V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC9235B36C0R-GDC-DC converter, TorexDC-DC converterTorex
      What it is
      DC-DC converter
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 3.6V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC9235B36C4R-GDC-DC converter, TorexDC-DC converterTorex
      What it is
      DC-DC converter
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 3.6V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as CD6

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with CD6

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 2 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.